Newport 918D-IG-C1-OD2 Low Power Detector/Sensor
Model/Part No.: 918D-IG-C1-OD2
Price:    $995.00

Purchase This Item
Details Details:
Includes: Sold As Pictured.

D10
Description Description:
Manufacturer's Information Manufacturer's Information:
The 918D Series Low-Power Detectors were developed to interface with our next generation power meters (see High-Performance Optical Meters, High-Performance Hand-Held Optical Power and Energy Meter, Hand-Held Optical Power and Energy Meter, Hand-Held Optical Power Meter) utilizing a 15-pin D-Sub connector to expand signal handling capability. The 918D Series is designed to perform similar to Newport's industry proven 818 Series low-power detector family (see Low-Power Detectors), while enhancing their performance with advanced features. 918D Series: The detectors feature integrated calibration-data storage, integrated OD1, OD2 or OD3 attenuation filter with electronic position sensing (attenuator On/Off), thermo-electric cooler (model 918D-IG-C1) and temperature sensing electronics for temperature drift compensation, making the detector more accurate in environments with small temperature fluctuations. The 918D models offer one of three choices on built-in attenuation filters. As with all other Newport detectors, the 918D Series include a full spectral response calibration utilizing NIST-traceable standards calibrated with high-precision equipment maintained in Newport’s Optical Metrology facility. Each detector is shipped with its individual calibration data, which is electronically stored inside the detector's EEPROM. A certificate of calibration as well as the actual calibration curves are shipped with the detector for attenuator and no attenuator modes.
Specifications Specifications:
(1200–2550 nm)
Spectral Range (mm) 1.2–2.55
Power, Average Max w/ Attenuator (W/cm2) 2
Power, Average Maximum w/o Attenuator (mW/cm2) 3
Pulse Energy, Maximum - w/ Attenuator (mJ/cm2) 0.35
Pulse Energy, Maximum - w/o Attenuator (nJ/cm2) 0.35
Calibration Uncertainty (Without Attenuator) 5% @ 1200-1390nm, 4% @ 1400-2520nm, 8% @ 2530-2540nm
Uniformity (%) ±2
Linearity (%) ±5
Saturation Current (mA) 2
Responsivity ł0.1 A/W 1200–2550 nm
Responsivity (Peak) >1.1 A/W
Rise Time (ms) Ł100 (ns)
Shunt Resistance (MW) (typ) ł60 (kW)
Die Capacitance (pF) 200
Reverse Bias, Maximum (V) 2
 
 
 